Aug 27, 2026
$9.4K
Install ul tested stainless steal liner down the existing flue pipe. will run from top of chimney to the smoke chamber. seal smoke chamber with high heater refractory cement. attach rain cap/spark arrester.
1060 Francisco StRussian Hillcomplete
Aug 11, 2026
$22.6K
Living room - install ul listed stainless stell liner down the (e) terrecotta flue. seal bottom with high temperature refractory mortar. install plate steel damper. attach rain cap/spark arrester on top. master bedroom do the exact same work in this room - stainless liner with rain cap/spark arreste
29 West Clay StSeacliffcomplete
Jul 7, 2026
$18.8K
Apply heat shield refractory flue sealant to interior of both fireplace flues. ul listed material. apply smoketite-high heat refractory to both smoke chambers.
2466 Union StMarinacomplete
May 28, 2026
$14.5K
Install new seliak all fuel chimey system on roof, ul listed flue pipes, seal smoke chamber with smoke tite high heat cement. install new plate steel damper.
1318 York StMissioncomplete
May 26, 2026
No cost listed
Work category: 1m; install jotul model gf300 dv freestanding gas fireplace pursuant to manufacturers instructions. direct-vent pipe off of the appliance thru the ceiling to the roof top termination... fire - stop(s) set as needed.... install roof flashing,rain cap, and storm collar on chimney surface....we are only running the flue pipe system, nothing else.
1948 Great HySunset/Parksideissued#Heating & cooling
May 26, 2026
No cost listed
Work category: 1m; install on the top floor, a jotul, model gf 300 dv freestanding gas fireplace pursuant to the manufacturers instructions. direct-vent flue pipe off of the appliance thru the ceiling to the roof top termination. fire-stop(s) set as needed .... install roof flashing, rain cap, and storm collar on the chimney surface. we are only running the flue pipe system....
1950 Great HySunset/Parksideissued#Heating & cooling
Jan 13, 2026
$15.4K
Living room fireplace: pardge smoke chamber w/ high-temperature cement - smokelite. run all stainless steel doublewalls metalbestos flue from starter plate to chimney surface. unlisted - solid pack piper install fire stops. new flue terminates within (e) chase. attach rain cap w/ spark arrester.
3740 Clay StPresidio Heightscomplete
Jan 7, 2026
$8.8K
Reline (e) interior chimney flue w/ all approved stainless steel liner. seal smoke chamber and bottom of new liner w/ high temparture refractory cement. install plate steel rooftop damper w/ ss. cable running to "stop" at fireplace opening. attach rain cap/spark arrests. no change to fireplace...
1504 18th AvInner Sunsetcomplete
Dec 20, 2025
No cost listed
Work category: 1m; living room —-pardge smoke chamber with high temp cement, set metalbestos anchor plate - run all stainless steel metalbestos flue system. ul listed, solid pack pipe. install firestops. new flue will terminate within existing chimney chase. attach high wind cap with spark arrester.
3740 Clay StPresidio Heightscanceled#Heating & cooling
Oct 29, 2025
No cost listed
Work category: 1m; this is a mechanical permit application - not plumbing for an open brick fireplace reline interior chimney flue with ul approved stainless steel liner. seal smoke chamber area and bottom of new liner with high temperature refractory cement. install plate steel rooftop damper with cable running to "stop" at fireplace opening. attach rain cap/spark arrester to top of new chimney flue. fireplace fascia will remain and look the same. no change. this process will make the interior flue safer.
1504 18th AvInner Sunsetcanceled#Heating & cooling#Plumbing
Oct 22, 2025
No cost listed
Work category: 1m; installed regency model contura free standing gas stove in the front living room. unit was installed pursuant to manufacturer instructions with dura-vent manufactured flue pipe. this is a vertical direct vent flue system.
2154 42nd AvSunset/Parksidecomplete#Heating & cooling
Jul 29, 2025
No cost listed
Work category: 1m; interior chimney repair with heat shield cerfractory flue sealant.... listed to ul 1777. we are resealing existing interior flue tiles... no change to fireplace fascia. exterior remains the same.
2090 Pacific AvPacific Heightsexpired#Heating & cooling
Oct 23, 2024
No cost listed
Work category: 1m; line interior chimney with type 304, 24 gauge stainless steel from top of smoke chamber to chimney surface. fill voids in smoke chamber with high temperature cement. install rain cap/spark arrester to top of chimney.
152 28th AvSeacliffcomplete#Heating & cooling
Jul 18, 2024
No cost listed
Install gas logs to existing fireplace - gas line with dante valve already in place. within 3' radius of opening. radiant artificial gas logs.
1100 Union StRussian Hillcomplete#Plumbing
Jul 18, 2024
No cost listed
Replace chimney caps on fireplaces attached wind directional cap - remove rusted old caps.
1100 Union StRussian Hillcomplete#Plumbing
Apr 25, 2024
No cost listed
Minor repairs - insert installation gas mdc valor attach flue pipe to appliance. run to top of existing chimey. attach cap, gas work done by others.
14 Montezuma StBernal Heightscomplete#Plumbing
Apr 23, 2024
No cost listed
To obtain final inspections for previously approved permit pmw20220217920 .
14 Montezuma StBernal Heightsfiled