Contractor on San Francisco permit records
This page is built from public San Francisco permit records. It shows permits this firm pulled, not the quality of its work, and it isn't a recommendation. We don't check whether a contractor is currently licensed, bonded or insured. Verify that at the CSLB before you hire.
SF jobs on record
0
Jobs in the past year
0
Typical job size
—
Most recent job
3mo ago
Jul 9, 2026
16 permits on record. Values are declared at filing.
Jul 9, 2026
No cost listed
Ran new circuit in garage and outlets.
446 34th AvOuter Richmondcomplete#Electrical
Mar 24, 2025
No cost listed
Upgrade main service panel from 125amp to 400amp. add 2 meters for new apartments
490 Collingwood StNoe Valleyissued#Electrical
Feb 26, 2025
No cost listed
Install ufer ground in foundation
490 Collingwood StNoe Valleyissued#Electrical
Nov 26, 2024
No cost listed
Replacing existing main panel fuse service and relocation with a 400a siemens panel with 6 meters.
1 Clipper StNoe Valleyissued#Electrical
Jan 16, 2024
No cost listed
Final inspection for work done on previous permit.
4300 23rd StNoe Valleycomplete
Dec 18, 2023
No cost listed
Installing a circuit for an electric water heater and a circuit for a heat pump.
201 Christopher DrInner Sunsetcomplete#Water heater#Heating & cooling#Electrical
May 8, 2023
No cost listed
Upgrading old main panel to a 200 amp panel
507 Brunswick StExcelsiorissued#Electrical
Jul 29, 2021
No cost listed
Add 7 20amp outlets in garage, gfic protected
4288 24th StNoe Valleycomplete#Electrical
Aug 19, 2019
No cost listed
Apt #2. upgrade subpanel in closets of 8 units bldg. (1) 30 amp service. 3 wires #10 feeder. 3 circuits, 4 lights, 4 switches, 8 receptacles, 2 smoke detectors.
490 Collingwood StNoe Valleycomplete#Electrical
Aug 19, 2019
No cost listed
Apt #8. upgrade subpanel in closets of 8 units bldg. (1) 30 amp service. 3 wires #10 feeder. 3 circuits, 4 lights, 4 switches, 8 receptacles, 2 smoke detectors.
490 Collingwood StNoe Valleycomplete#Electrical
Aug 19, 2019
No cost listed
Apt #7. upgrade subpanel in closets of 8 units bldg. (1) 30 amp service. 3 wires #10 feeder. 3 circuits, 4 lights, 4 switches, 8 receptacles, 2 smoke detectors.
490 Collingwood StNoe Valleycomplete#Electrical
Aug 19, 2019
No cost listed
Apt #3. upgrade subpanel in closets of 8 units bldg. (1) 30 amp service. 3 wires #10 feeder. 3 circuits, 4 lights, 4 switches, 8 receptacles, 2 smoke detectors.
490 Collingwood StNoe Valleycomplete#Electrical
Aug 19, 2019
No cost listed
Apt #1. upgrade subpanel in closets of 8 units bldg. (1) 30 amp service. 3 wires #10 feeder. 3 circuits, 4 lights, 4 switches, 8 receptacles, 2 smoke detectors.
490 Collingwood StNoe Valleycomplete#Electrical
Aug 19, 2019
No cost listed
Apt #5. upgrade subpanel in closets of 8 units bldg. (1) 30 amp service. 3 wires #10 feeder. 3 circuits, 4 lights, 4 switches, 8 receptacles, 2 smoke detectors.
490 Collingwood StNoe Valleycomplete#Electrical
Aug 19, 2019
No cost listed
Apt #6. upgrade subpanel in closets of 8 units bldg. (1) 30 amp service. 3 wires #10 feeder. 3 circuits, 4 lights, 4 switches, 8 receptacles, 2 smoke detectors.
490 Collingwood StNoe Valleycomplete#Electrical
Aug 19, 2019
No cost listed
Apt #4. upgrade subpanel in closets of 8 units bldg. (1) 30 amp service. 3 wires #10 feeder. 3 circuits, 4 lights, 4 switches, 8 receptacles, 2 smoke detectors.
490 Collingwood StNoe Valleycomplete#Electrical